TECNOPRESS Bursting Panels in production and in our warehouse

Domed TECNOPRESS Bursting Panels

External dimensions
[mm]
Effective Discharge Area
[m²]
*
Effective Discharge Area
with back-pressure frame [m²]*
970 x 510 0,4013 0,3800
690 x 550 0,2890 0,2700

* Calculated in consideration of the opening efficiency


All the models listed above have:

Bursting pressure: 0,1 bar (with a tollerance identified by tests carried out on each production batch up to a maximum of ±50%) at 25°C. Venting efficiency: 0,95
Relative operating pressure allowed: + 0,06 bar Certification: CE 0588 Ex GD FSA 05 ATEX 1558 X
Allowed operating negative pressure: - 0,04 bar
(without back-pressure frame)
Maximum operating values allowed:
Kst = 300 bar•m•s-1 Pmax = 10 bar
Kg = 100 bar•m•s-1 Pred-max = 2 bar

 

Flat and Ribbed TECNOPRESS Bursting Panels

External dimensions
[mm]
Effective Discharge Area
[m²]
*
309 x 309 0,057
370 x 285 0,064
385 x 309 0,075
500 x 300 0,10
445 x 400 0,12
500 x 400 0,14
537 x 385 0,14
690 x 327 0,16
External dimensions
[mm]
Effective Discharge Area
[m²]
*
700 x 380 0,19
570 x 570 0,24
735 x 455 0,25
690 x 550 0,29
670 x 570 0,29
690 x 690 0,37
970 x 510 0,38
788 x 645 0,40

* Calculated in consideration of the opening efficiency

External dimensions
[mm]
Effective Discharge Area
[m²]
*
400 x 200 0,042
550 x 250 0,086

* Calculated in consideration of the opening efficiency

All the models listed above have:

Bursting pressure: 0,1 bar (with a tollerance identified by tests carried out on each production batch up to a maximum of ±50%) at 25°C. Venting efficiency: 0,95
Relative operating pressure allowed: + 0,05 bar Certification: CE 0588 Ex GD FSA 05 ATEX 1558 X
Allowed operating negative pressure: - 0,05 bar
(without back-pressure frame)
Maximum operating values allowed:
Kst = 300 bar•m•s-1 Pmax = 10 bar
Kg = 100 bar•m•s-1 Pred-max = 2 bar



TECNOPRESS bursting panels - non-standard dimensions

Flat TECNOPRESS Bursting Panels

External dimensions
[mm]
Effective Discharge Area
[m²]
*
Effective Discharge Area
with back-pressure frame [m²]*
550 x 350 0,122839 NP(**)
1150 x 1150 1,3225 1,055599

Ribbed TECNOPRESS Bursting Panels

External dimensions
[mm]
Effective Discharge Area
[m²]
*
Effective Discharge Area
with back-pressure frame [m²]*
755 x 650 0,360898 0,348198
972 x 539 0,384053 0,370013
1000 x 730 0,556477 0,537995
1150 x 1002 0,91121 NP(**)
970 x 490 0,343339 0,334739

* Calculated in consideration of the opening efficiency

** Can be calculated by request

All the models listed above have:

Bursting pressure: 0,1 bar (with a tollerance identified by tests carried out on each production batch up to a maximum of ±50%) at 25°C. Venting efficiency: 0,95
Relative operating pressure allowed: + 0,05 bar Certification: CE 0588 Ex GD FSA 05 ATEX 1558 X
Allowed operating negative pressure: - 0,05 bar
(without back-pressure frame)
Maximum operating values allowed:
Kst = 300 bar•m•s-1 Pmax = 10 bar
Kg = 100 bar•m•s-1 Pred-max = 2 bar
 

Company News

Since its foundation in 1987, Tecnopress has has doistinguished itseft through an ability to offer concrete support to its clients in their choice of solutions, from the design phase right through to manufacturing.

Read more...

Atex News

This type of safety device – in accordance with standard UNI EN 14491:2006 – is designed for the protection against possible explosions caused by a sudden increase in pressure within equipment containing a potentially-explosive air/dust mixture such as silos, filter separators, elevators, sieves, blenders, storage tanks, ducts, dust collectors, dryers, etc.

 